Why Moving the EUT Changes the Emissions Plot
- Francesco Poderico

- 22 hours ago
- 3 min read
1. Introduction – why a small change can make great differences in the plot
Did this happen to you. You go to the testing lab. you do a full RE scan and the scan looks great. Then you
Rotate the EUT 90°
Lift a cable
Move the EUT by 20 cm
Change cable routing
And the emissions plot changes.
This is not randomness. It is physics.
Radiated EMC measurements are strongly influenced by how the product couples to its environment.
I want to discuss this today, so, next time, when you are in a chambe and youmove a cable, or move the EUT, change a cable, etc. you can quickly identify the issue.
2. The Cable Is the Real Antenna
Most electronics products:
The PCB is small
The cables are long
Long conductors carrying common-mode current behave as antennas.
Why Common-Mode Current Radiates
Common-mode current flows:
In the same direction on all conductors
Returning through parasitic capacitance to ground
Using the chamber ground plane as a return path
Even a few milliamps of CM current at 30–200 MHz can radiate significantly.

In a RE chamber the common mode path is artificially controlled by the test setup.
What Happens When You Move the Cable
Changing cable position changes:
Its effective antenna length
Its height above the ground plane
Its orientation relative to the measurement antenna
Its coupling to the EUT enclosure
The radiated field changes accordingly.
This is why lifting a cable off the table can increase emissions.
3. Height Above Ground Plane: Image Theory in Practice
In a semi-anechoic chamber:
The floor is conductive
The EUT sits on a table (typically 80 cm high)
The conductive floor creates an “image” of the cable (image theory do you remember we study this at the uni).
When you change:
EUT height (by adding a cardboard box under the EUT)
Cable droop
You change:
The effective antenna structure
The radiation pattern
The field strength at the measurement antenna
Small height changes can produce several dB variation.
So... by moving the EUT of ... say 10 cm "up" you have a emission reduction. then CM emission is happening.

4. Rotating the EUT: Polarization and Radiation Pattern
Rotating the EUT changes:
The orientation of the dominant radiating structure
The polarization of the field
The coupling between cable and antenna
Radiation is directional.
If the dominant current path is aligned with the antenna polarization, the measured level increases.
If it is orthogonal, it decreases.
This explains why:
0°, 90°, and 180° positions can show different peaks
Some frequencies are more sensitive than others
5. How to Interpret These Changes During Debugging
When emissions change after moving the EUT:
If rotating the product changes amplitude significantly:
The product has directional radiation (likely cable-driven).
If lifting the cable increases emissions:
Strong common-mode coupling to the ground plane.
If twisting the cable reduces emissions:
Radiation dominated by loop area.
If touching the enclosure changes emissions:
Poor enclosure bonding or floating metal parts.
Movement is a diagnostic tool — not a nuisance.
6. Practical Debug Strategy
During pre-scan:
Intentionally move cables
Rotate the EUT
Lift and drop cables
Lift the EUT
Change cable routing
If emissions are unstable:
You likely have common-mode current problems
Filtering or return path control needs improvement
A robust design shows limited sensitivity to cable position.
7. Conclusion
If your emissions plot changes when you move the EUT, it does not mean the test is unreliable.
It means:
The product is interacting with its environment.
Cables are radiating.
Common-mode current exists.
Understanding this allows you to use movement as a diagnostic method rather than treating it as noise in the measurement.